Power Factor Correction with Synchronous Condenser for Power Quality Improvement in Industrial Load
Keywords: inductive type, power factor, power quality, synchronous condenser, induction motor, lagging, leading
As most of loads are of inductive type, the power system is in lagging power factor and as a result poor power quality is
occurred. And it is demanded to make power factor correction to be better power quality of power system. Among power factor
correction devices, synchronous condenser is studied in this paper to improve the industrial loads. There are ten numbers of induction motors in Tharpaung pulp plant and the net power factor of the factory power system is round about 0.85 lagging. By using 0.75 leading power factor of synchronous condenser, the system power factor is improved to 0.969 lagging. And it is studied to choose the appropriated synchronous condenser of power factor and rating for various system power factors. And if there are different operating times for each induction motors, which synchronous condenser should be run is studied in detail in the paper. It is shown that the use of synchronous condenser improves the system power factor and makes power quality better. In this study, MATLAB program is used for overall plant power factor calculation.
C. Sankaran, Power Quality, CRC Press LLC, Printed in
the United States of America, 2002.
+5V-Powered, Multichannel RS-232 Drivers/Receivers,
May 2005, http://www.maxim.ic.com/packages..
Data Sheet of Silicon Epitaxial Planner Type Diode,
1S1585_1S1588, February 2006,
http://www.datasheetarchive.com.
John Webb/Kevin Greshock, Industrial Control
Electronic, May 2003.
Leonard L. Grigsby, Electric Power Generation,
Transmission and Distribution, Talor and Francis Group, CRC
Press LLC, 2006.
R. Sastry Vedam Mulukutla and S. Sarma, Power
Quality VAR Compensation in Power Systems, Tallor and
Francis Group, CRC Press LLC, 2009.
Roger C.Dugan, Mark F. McGranaghan, Surya Santoso,
H. Wayna Beaty, Electrical Power System Quality, Second
edition, 2004 by Mc Graw-Hill.
Hand Book of Power Quality, edited by Angelo Baggini,
University of Bergamo, Italy, copyright by John Wiley and
Sons Ltd, 2008.
@article{MoeKay03031002,
title = " Power Factor Correction with Synchronous Condenser
for Power Quality Improvement in Industrial Load ",
journal = "International Journal of Science and Engineering Applications (IJSEA)",
volume = "3",
number = "3",
pages = "39 - 43",
year = "2014",
author = " Moe Kay Thi Khaing ",
}